Single strand or Multi Stranded wiring cable UL (AWM)-CSA Recognized. International approved Single Core Style 1007, 1015, 1032, 1569 with Different Temp.range and voltage grade depending upon requirment with wide range.
International approved Multi Core Jacketed Cable Style 2464 with or without shielding.
Working Temperature Range:
Nominal Voltage Grade:
Conductor: (solid/stranded)
Test Voltage:
80℃
300V
22-16AWG
2000V
80℃,90℃
or105℃
300V
22-16AWG
2000V
Part # | Sizes in AWG | Apprx.Dia.in MM (+/- 0.20mm) | |
---|---|---|---|
33324 | 24 | 1.50 | |
33322 | 22 | 1.60 | |
33320 | 20 | 1.70 | |
33318 | 18 | 2.00 | |
33316 | 16 | 2.40 | |
(Any other size on request) |
For Reference Only*
Working Temperature Range:
Nominal Voltage Grade:
Conductor:
Test Voltage:
Use:
80℃,90℃ or 105℃
600AC, 750DC
22 AWG to 1/0 AWG
Multi stranded in combination to get
nearest AWG cross section
upto 2 AWG 2 KV
1 to 4/0AWG 2.50KV
Appliance Wiring & Panel Wiring
Part # | Sizes in AWG | Apprx.Dia.in MM (+/- 0.20mm) |
---|---|---|
33324 | 24 | 2.20 |
33322 | 22 | 2.30 |
33320 | 20 | 2.50 |
33318 | 18 | 2.70 |
33316 | 16 | 3.00 |
33314 | 14 | 3.40 |
33312 | 12 | 3.90 |
33310 | 10 | 4.50 |
33308 | 8 | 6.00 |
33306 | 6 | 7.80 |
33304 | 4 | 9.00 |
33302 | 2 | 10.50 |
33301 | 1 | 12.70 |
3331/0 | 1/0 | 14.00 |
(Any other size on request) |
For Reference Only*
Scope: PVC Insulated Wire
Working Temperature
Nominal Voltage
Conductor:
Test Voltage:
90℃
1000 VAC or 1200 VDC
Solid / Multistrands
3000 V
Part # | Sizes in AWG | Apprx.Dia.in MM (-0.50mm +0.20mm) |
---|---|---|
33320 | 20 | 2.50 |
33318 | 18 | 2.70 |
33316 | 16 | 3.00 |
33314 | 14 | 3.40 |
33312 | 12 | 3.90 |
33310 | 10 | 4.50 |
33308 | 8 | 6.00 |
33306 | 6 | 7.80 |
33304 | 4 | 9.00 |
33302 | 2 | 10.50 |
33301 | 1 | 12.80 |
3331/0 | 1/0 | 14.00 |
3332/0 | 2/0 | 15.00 |
3333/0 | 3/0 | 16.50 |
3334/0 | 4/0 | 18.00 |
333250 | 250kcmil | 20.00 |
333300 | 300kcmil | 21.30 |
(Any other size on request) |
For Reference Only*
Scope: PVC Insulated & Jacketed Multicore with or without shield
Working Temperature Range:
Test Voltage:
Conductor:
Test Voltage:
Color:
Jacket:
Conductor Size:
Core test:
Number of cores:
80℃
Between core conductors 2000v
Between core to Shield 1500v
Solid / Flexible
300V
White with Black printed numbers One core Yellow/Green for use as earth conductor
Grey or Black
24 AWG to 16AWG (solid/flexible)
(Any other size on request)
Ref. to Style No: 1007 80℃
Style No: 1569 80℃
upto 24 core (Any other size on request)
Calculated dia of round assembly Inch(mm) | Avg | Min | Avg | Min |
---|---|---|---|---|
0-0.70inch (0.17.78mm) | 0.03 | 0.024 | 0.76 | 0.61 |
0-0.70inch (17.79mm to 25.40mm) | 0.045 | 0.036 | 1.14 | 0.91 |
1.01-1 .50inch (25.41mm to 38.1mm) | 0.06 | 0.048 | 1.52 | 1.22 |
For Reference Only*
Scope: PVC Insulated & Jacketed Multicore with or without shield
Working Temperature Range:
Test Voltage:
Conductor:
Test Voltage:
Color:
Jacket:
Conductor Size:
Core test:
Number of cores:
Conditionally Resistance to:
UL Flame Rating
Canadian Recognition
-20 to +105˚C
Between core conductors 2000v Between core to Shield 1500v
Solid / Flexible
600V & 1000V
White with Black printed numbers One core Yellow/Green for use as earth conductor
Grey or Black
26AWG to 2/0 AWG (Multistranded) (Any other size on request)
Ref. to Style No: 1015 105℃
upto 24 core (Any other size on request)
Oil, Solvents, Acids & dyes.
VW1, FT1/FT2
I A&B (CSA 22.2 No. 210:TEW, FT1, FT2 & IEC 60332-1 (Europe)
Scope: PVC Insulated & Jacketed Multicore with or without shield
Working Temperature Range:
Test Voltage:
Conductor:
Voltage:
Color:
Jacket:
Conductor Size:
Core test:
Number of cores:
Conditionally Resistance to:
UL Flame Rating
Canadian Recognition
-20 to +105˚C
Between core conductors 2000v Between core to Shield 1500v
Solid / Flexible
600V
White with Black printed numbers One core Yellow/Green for use as earth conductor
Grey or Black
26AWG to 2/0 AWG (Multistranded) (Any other size on request)
Ref. to Style No: 1015 105℃/p>
upto 2 to 7 Cores (Any other size on request)
Oil, Solvents, Acids & dyes.
VW1, Horizontal flame
I A&B (CSA 22.2 No. 210:TEW, FT1, FT2 & IEC 60332-1 (Europe)